Virtual Connect modules 254
Integrity blade devices
Server Bay Overall Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot be
determined.
Check Onboard Administrator
communication.
(blue)
Initializing Device is initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(blue)
Profile pending Device has a pending profile
assignment.
The profile might need changes that
require power cycling the server. This
might be a result of restoring a
configuration while the server is
powered on. Verify that the server
connectivity is correct. To clear the
profile pending state, power cycle the
server. Any necessary changes are
made when the server is powered off.
(yellow)
Degraded Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
Misconfigured Device has a configuration error. Correct the Virtual Connect Manager
Comentarios a estos manuales