Server QOS 8-Bay Guía de usuario Pagina 255

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 308
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 254
Virtual Connect modules 255
Icon Operational state Meaning Corrective action
(orange) configuration attributes.
(orange)
Incompatible Device does not match the
configuration.
BIOS version level is not at a level that
supports Virtual Connect.
(orange)
No communication Cannot communicate with the
device.
Check the physical connections and IP
address.
(orange)
Missing data VCM is missing data about one or
more blades in the multi-blade
server.
Check that the blades and Blade Link
that comprise the multi-blade server are
installed correctly and functioning
properly.
Missing Device is configured but not
accessible.
Insert the correct hardware module.
Failed Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Server Bay OA Reported Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot be
determined.
Check Onboard Administrator
communication.
(yellow)
Degraded Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
Failed Device is not operational because
of an error.
Check and correct the Onboard
Administrator error condition.
Server Bay VC Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot be
determined.
Check Onboard Administrator
communication.
Disabled Device is disabled. Enable the component in Virtual
Connect Manager.
(blue)
Initializing Device is initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(blue)
Profile pending
Device has a pending profile
assignment.
Turn server power off and apply the
new profile.
(yellow)
Degraded Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
(orange)
Misconfigured Device has a configuration error. Correct the Virtual Connect Manager
configuration attributes.
(orange)
Incompatible
Device does not match the
configuration.
BIOS level is not at a level that supports
Virtual Connect.
(orange)
No communication Cannot communicate with the
device.
Check the physical connections and IP
address.
Vista de pagina 254